Modbus Integration ​

Function path: SVE navigation bar → Result Integration → Modbus


Overview ​

The smart camera acts as a Modbus Master, writing AI inference results via TCP to the Coils or Holding Registers of the remote Modbus Slave. Suitable for interfacing with PLCs / gateways / HMIs — transmits only signal-level results (OK/NG status words), not images.

Integration Requirements ​

ItemRequirement
Communication ModeTCP (camera as Master); RTU requires serial slave support on the remote end
Slave DeviceModbus Slave accessible by the camera (PLC / gateway / slave simulator), with corresponding data areas enabled
IP AddressSlave IP (camera-reachable)
PortSlave listening port (default 502, per actual slave configuration)
Slave IDSlave station number (range 1~247)
Data AreaCoil / Holding Register, select based on what the slave supports
AddressData area start address (range 0~65535, per actual slave)
Write ValueCoil: ON (0xFF00) / OFF (0x0000); Register: 0~65535 numeric value
Trigger ConditionResult is OK / Result is NG / Any result

Basic Configuration on SVE ​

  1. Navigate to Result Integration → Modbus;
  2. Turn on the Modbus Integration switch;
  3. Fill in/select parameters:
ParameterDescription
Communication ModeTCP (default) / RTU
IP AddressSlave IP (required for TCP mode)
PortSlave listening port (default 502, per actual slave)
Slave IDSlave station number (1~247, default 1)
Data AreaCoil / Holding Register
AddressData area address (0~65535, default 0)
Write ValueCoil: ON (0xFF00) / OFF (0x0000); Register: numeric value
Trigger Rule → Trigger ConditionResult is OK (default) / Result is NG / Any result
  1. Click Save.

Note: The "Port", "Slave ID", and "Address" on SVE are parameters for writing to the remote slave and must match the actual slave configuration.

Basic Verification ​

Page Testing (Test Send) ​

After configuration, click Test Send and observe the "Debug Request" area on the right: a success response indicates the link is normal (successfully wrote to the slave's corresponding address).

Real Task Verification ​

  1. Trigger an AI inference that meets the trigger condition (e.g., result is NG);
  2. Check the slave's data area: use a slave debug tool / slave simulator (Comms panel) to read the configured address — value == camera's configured write value → Integration successful.

Common Issues ​

SymptomTroubleshooting
Camera connection failed/no responseCheck if slave is started and listening on the configured port; IP/port/Slave ID matches the slave
Expected value not writtenTrigger condition met (OK/NG/any result); write value matches slave data area format (Coil/Register)
Slave does not support this data areaConfirm slave has the corresponding Coil/Register data area enabled
RTU connection failedCheck serial port parameters (baud rate/parity/station number) match the remote slave